CM1164 RS-232 Control Tool

Restore Default Value

The Restore Default Value command allows you to reset all of the CM1164’s settings back to the default. Use the Formula - to set Parameters - to create a Command.

Formulas:

Command + Control + [Enter]

Parameters:

Command

Description

 

 

redefault

Restore Default Value Command

 

 

 

 

Control

Description

 

 

on

Enable restore default values

 

 

 

 

Enter

Description

 

 

Enter

Enter and send out command

 

 

Restore Default Value Command

The available formula for the Restore Default Value command is as follows:

1. Command + Control + [Enter]

For example, to restore all CM1164 settings back to the default, type the following:

redefault on [Enter]

Note: Each command string can be separated with a space.