CS-1754 / CS-1758 User Manual

(Continued from previous page.)

Setting

Function

 

 

PORT ID

Selects how the Port ID is displayed: the Port Number alone

DISPLAY

(PORT NUMBER); the Port Name alone (PORT NAME); or the

MODE

Port Number plus the Port Name (PORT NUMBER + PORT

 

NAME). The default is PORT NUMBER + PORT NAME).

 

 

SCAN

Determines how long the focus dwells on each port as it cycles

DURATION

through the selected ports in Auto Scan Mode (see F7 SCAN,

 

page 32). Key in a value from 1 - 255 seconds, then press [Enter].

 

Default is 5 seconds; a setting of 0 disables the Scan function.

 

 

SCAN/SKIP

Selects which computers will be accessed under Auto Scan Mode

MODE

(see F7 SCAN, page 32). Choices are:

 

ALL - All the Ports which have been set Accessible (see SET

 

ACCESSIBLE PORTS, page 31);

 

POWERED ON - Only those Ports which have been set Accessible

 

and are Powered On;

 

QUICK VIEW - Only those Ports which have been set Accessible

 

and have been selected as Quick View Ports (see SET QUICK

 

VIEW PORTS, page 31);

 

QUICK VIEW + POWERED ON - Only those Ports which have

 

been set Accessible and have been selected as Quick View Ports

 

and are Powered On. The default is ALL.

 

Note: The Quick View choices only show up on the administrator's

 

screen, since only the administrator has Quick View setting rights

 

(see SET QUICK VIEW PORTS, page 31, for details).

 

 

SCREEN

If there is no input from the console for the amount of time set with

BLANKER

this function, the screen is blanked. Key in a value from

 

1 - 30 minutes, then press [Enter]. A setting of 0 disables this

 

function. The default is 0 (disabled).

 

 

HOTKEY

Enables / Disables the Hotkey function (see Hotkey Operation,

COMMAND

page 35) in case there is a conflict with programs running on the

MODE

computers. On enables the function, Off disables it. The default is

 

On.

 

 

28