ATEN Technology CS-88A user manual Powering Off and Restarting

Models: CS-88A

1 41
Download 41 pages 7.69 Kb
Page 16
Image 16

Powering Off and Restarting

If it becomes necessary to Power Off one of the Master View units, before starting it back up you must do the following:

1.Shut down all the computers that are attached to the unit. If there are Master View stations cascaded down from it, all the cascaded stations and the computers attached to them must be shut down, as well.

Note: 1. You must unplug the power cords of any computers that have the Keyboard Power On function that are connected to the shut down switches. Otherwise, the switches will still receive power from the computers.

2.If the unit is operating under external power, unplug the power adapter cable.

2.Wait 10 seconds, then plug the stations back in, starting with the lowest stations in the chain and working back to the station you originally shut down.

3.After all the Master View’s are up, power On the computers, starting with the ones attached to the lowest stations in the chain and working back to the station you originally shut down.

12

CS-88A User Manual

2002-12-27

Page 16
Image 16
ATEN Technology CS-88A user manual Powering Off and Restarting