KL3116 / KL3116T User Manual
(Continued from previous page.)
TWO-POINT Note: This function is available on the KL3116T only. CALIBRATION Calibrates the touchscreen for use on ports with a connected
computer.
Note: 1. Before using two-point calibration, be sure to select a port with a working computer attached, otherwise the calibration will not be started.
2.Two-point calibration must be used when calibrating a port for the first time.
3.If the calibration process is interrupted at any time (accidentally switching ports, for example), press [ESC] to exit and start the calibration process again.
To perform a two-point calibration:
1.Use the touchpad or an externally connected USB mouse to move the pointer near the upper left corner of the screen; then, touch the pointer as instructed on-screen.
2.Use the touchpad or an externally connected USB mouse to move the pointer near the lower right corner of the screen; then, touch the pointer as instructed on-screen.
ONE-POINT Note: This function is available on the KL3116T only. CALIBRATION Use this function to quickly and easily recalibrate the touchscreen
with a single point.
Note: 1. Before using one-point calibration, be sure to select a port with a working computer attached, otherwise the calibration will not be started.
2.Two-point calibration must first have been performed on the selected port before attempting a one-point calibration. If the switch senses that a two-point calibration has not been performed on the port, the one- point calibration will not be started.
3.An even easier method of resynchronizing the on-screen pointer can be found under Alternative Touchscreen Pointer Synchronization, page 79.
To perform a one-point calibration:
1.If necessary, use the touchpad or an externally connected USB mouse to move the pointer so that it is visible on the screen.
2.Touch the pointer as instructed on-screen.