4.2 Additional Controls for AV32, AV48, AV64, AV96, AV128

“UNDO”

Undo button: To resume to the status before the command just performed

“PROGRAM” Group programming button: To define, recall and clear a group of output channel Example1: To group the output channels No.1,2,3,4,5 under the Group1

Operation: Press buttons in this order “1”, “Program”, “Program”, “1”, “2”, “3”, “4”, “5”

Example2: To transfer signals from input channel No.1 to Group2

Operation: Press buttons in this order “1”, “Program”, “2”

Example3: To clear the output channels under Group1

Operation: Press buttons in this order “1”, “Program”, “0”

Note: Please clear the group to be set before grouping it.

“ ← ”

Backspace button: To backspace the latest input button

 

“THROUGH” Through button: To transfer the signals directly to the corresponding output

 

channels

 

Example: To transfer the signals from input channels No.1,2,3 to their corresponding

 

output channels

 

Operation: Press buttons in this order “1”, “/”, “2”, “/”, “3”, “THROUGH”

“CLOSE”

Close button: To switch off the output channels

 

Example: To switch off the output channels No.1,2

 

Operation: Press buttons in this order “1”, “END”, “2”, “END”, “CLOSE”

“LOCK”

Lock button: To lock buttons on the front control panel by pressing it for 3 seconds

 

Note: When the control panel is being locked, the switcher still can be control via the

 

RS232 port. To unlock it, a password is needed.

“DEMO”

Demo button: To demonstrate the commands one by one every 3 seconds.

Atlona Technologies