Lincoln 1100 Series service manual Trouble Shooting Guide Gas Ovens

Models: 1100 Series

1 92
Download 92 pages 44.78 Kb
Page 25
Image 25

TROUBLE SHOOTING GUIDE

GAS OVENS

MODELS 1152 - 1153 - 1154 - 1155 - 1156 - 1157 - 1158

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check circuit breakers, reset if

 

 

required, call power company if needed.

 

Main Fan Switch

Check continuity between switch

 

 

terminals.

 

Control Box High Limit

Terminals are normally closed, and

 

Thermostat

open at 170°F ± 5F (76.6°C ± 2.8°C).

 

NOTE: Discontinued at

Check for over heating and reset

 

S/N 2011821

thermostat. Test for proper

 

 

operation. If it will not reset and hold, re-

 

 

place thermostat.

 

Fuse, 1 Amp

Check, replace if necessary.

 

Fuseholder

Check, replace if necessary.

 

Transformer,Step Down

120 VAC ± 10% should be present at

 

 

secondary of transformer. If proper

 

 

voltage is not present, check

 

 

transformer primary for proper

 

 

input. Replace as needed.

 

Oven Start Relay

Check for 120 VAC to relay coil. If

 

 

voltage is not present, trace wiring

 

 

back to power source. If voltage is

 

 

present, check to insure contact

 

 

is closing.

 

20 Minute Time Delay

Check for 120 VAC at terminal #1 to

 

 

neutral on 20 minute Time Delay

 

 

Relay. If no voltage is present, trace

 

 

wiring back to power source.

 

 

If voltage is present at terminal #1,

 

 

check for 120 VAC at terminal #2 to

 

 

neutral. If no voltage is present, and

 

 

cool down relay contact is closed,

 

 

replace Time Delay Relay.

 

Main Fan Relay

Check for 120 VAC to coil of the Relay

 

 

if no voltage is present, trace wiring

 

 

back to 20 minute Time Delay Relay.

 

 

If voltage is present, check to insure

 

 

contacts are closing.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuseholder

Check, replace if necessary.

 

Motor Capacitor

Check for opens, shorts, or grounds.

 

Main Fan Motor

Check for supply voltage to main fan

 

 

motor. If voltage is not present, trace

 

 

wiring back to main fan relay. Check for

 

 

opens, shorts, or grounds.

 

 

WITH POWER OFF: turn fan blade to

 

 

check for locked rotor.

Impinger II - 1100 Series Service Manual - International