Lincoln 1100 Series Cooling Fans, VAC should now be at these fan, motors. If voltage is present

Models: 1100 Series

1 92
Download 92 pages 44.78 Kb
Page 27
Image 27

 

Cooling Fans

120 VAC should now be at these fan

 

 

motors. If voltage is present,

 

 

check motors for shorts or opens.

 

 

WITH POWER OFF: Check for locked rotor.

Cooling fans continue

Cooling Fan Thermostat

Thermostat is normally open and may to run after

20 minute

 

have closed if control box temperature cool down

 

 

is 120°F or above.

Oven will not heat

Gas Supply

Check for adequate gas supply and

 

 

manual gas shut off valve is open.

 

 

Also, check flexible gas line connection.

 

Main Fan

If not operating, refer to “Oven Fan

 

 

Will Not Run” on Page C6.

 

Fuse 3 Amp

Check, replace if necessary.

 

Fuseholder

Check, replace if necessary.

 

Relay Oven Start

Supply voltage should be present

 

 

across these terminals.

 

Burner Switch

Check for supply voltage on both sides of

 

 

switch. If switch is closed and voltage

 

 

present on one side only, replace switch.

 

Gas Pressure Switch

This switch is located inside the gas

 

 

valve and should close when gas

 

 

pressure is present.

 

 

WITH POWER OFF: remove 3 prong plug

 

 

(on gas valve) and measure continuity between

 

 

terminals 2 and 3.

 

 

NOTE: Remove insulation pad below plug to

 

 

read numbers. If no continuity, check the

 

 

following:

 

 

Proper gas pressure supply to gas valve as

 

 

marked on the oven specification plate.

 

 

Check for proper adjustment of gas

 

 

pressure switch 8.8 on dial for

 

 

natural gas, 23 for LP, and

 

 

4.5 for Town Gas.

 

 

Check gas filter in gas valve for

 

 

blockage or damage. (See Adjustment

 

 

section for location)

 

 

If above checks are okay, but pressure

 

 

switch is still not closed, replace gas

 

 

valve.

 

Air Pressure

Check air switch terminals for supply voltage

 

Switch

at NO 2 and COM. If voltage is present on one

 

 

side only, check for air tube blockage or

 

 

misalignment. If these are okay, adjust

 

 

switch or replace necessary.

 

(Oven Cavity) High Limit

Terminals are normally closed, Thermostat

 

 

opens at 660°F (350°C). If

 

 

open, push in reset button and retest.

 

 

If thermostat will not hold for

 

 

maximum oven temperature, and oven

 

 

is not exceeding temperature dial

 

 

setting, check for proper location of

 

 

capillary bulb in its spring holder.

 

 

If above check okay, replace hi-limit

 

 

thermostat.

 

Ignition Control

Check for proper supply voltage

 

 

to ignition control.

Impinger II - 1100 Series Service Manual - International

27

Page 27
Image 27
Lincoln 1100 Series Cooling Fans, VAC should now be at these fan, motors. If voltage is present, Cooling fans continue