TROUBLE SHOOTING GUIDE

ELECTRIC OVENS

MODEL 1104

380/220 VAC

THREE PHASE

50 HZ

MODEL 1105

415/240 VAC

THREE PHASE

50 HZ

MODEL 1106

240 VAC

SINGLE PHASE

50 HZ

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

SYMPTON

POSSIBLE CAUSE

EVALUATION

 

Oven fan will not run

Incoming Power Supply

Check circuit breakers. Reset if required.

 

 

Call Power Co. if needed.

 

 

Fuse, 1 Amp,

Check, replace if necessary.

 

 

Fuseholder

Check, replace if necessary.

 

 

Switch, Main Fan

Check for continuity between switch terminals.

 

Transformer, Control

120 VAC ± 10% should be present

 

 

at secondary of transformer. If proper voltage is not

 

 

present, check transformer primary for proper input.

 

 

Replace as needed.

 

 

Main Fan Relay

Check continuity to 120 VAC coil. Check

 

 

for power to relay coil (120 VAC). Check for 220/240

 

 

VAC to the relay terminals. Check, replace

 

 

if necessary.

 

 

Fuse 10 A. Main Fan

Check, replace if necessary.

 

 

Fuse Holder

Check, replace if necessary.

 

 

Main Fan Motor

Check for opens, shorts, or grounds.

 

 

WITH POWER OFF: Turn fan blade to

 

 

check for locked rotor.

 

 

Capacitor

Check for opens, shorts, or grounds.

No control box cooling

 

Check for main fan operation. If not operating, refer

 

 

to “Oven fan will not run”.

 

 

Cooling Fan Motor

120 VAC should be present at the fan motor. If

 

 

voltage is present, check for opens or shorts.

 

 

WITH POWER OFF: Check for locked rotor

 

 

on fan motor.

 

No main fan cool down

Cool Down Thermostat

Check cool down thermostat (thermostat

 

 

closes at 160°F and opens at 140°F).

 

 

Check for power (220/240 VAC) at cool down thermo

 

 

stat. With cool down thermostat preheated, check for

 

 

continuity. If switch is open, replace.

Oven will not heat

Main Fan Motor

Check for main fan operation. If it is not

 

 

operating, refer to “Oven fan will not run”.

 

High Limit Thermostat,

Terminals are normally closed (open at

 

 

190°F). If open, reset the thermostat and

 

 

test for proper operation. If it will not reset and hold,

 

 

then replace.

 

34

Impinger II - 1100 Series Service Manual - International

Page 34
Image 34
Lincoln 1100 Series service manual Trouble Shooting Guide Electric Ovens