No main fan cool down | 20 Minute Time Delay | Check for 120 VAC at pin#2 and #3 |
| Relay | while main fan is running. Turn off |
|
| main fan switch and 120 VAC should |
|
| continue to be present for 20 minutes. |
| Main Fan Relay | Check if relay is operating and |
|
| terminals are remaining closed for |
|
| main fan cool down of 20 minutes. |
Main fan runs after |
| NOTE: The time delay relay will |
20 minute cool down |
| keep the coil of the main fan relay |
|
| closed, maintaining main fan operation for |
|
| cool down for approximately 20 minutes. |
| Cool Down Relay | Contacts of the relay should |
|
| open when main fan is switched off. |
| Time Delay | 120 VAC at terminal 2 should |
|
| discontinue approximately 20 minutes after main |
|
| fan is switched off. If cool down relay is open and |
|
| voltage continues at terminal 2, |
|
| replace time delay. |
| Main Fan Relay | When voltage at terminal 2 of time |
|
| delay ceases, main fan relay must open. |
No control box cooling | Incoming Power | Check main circuit breakers, reset if |
|
| required, call power company if |
|
| needed. |
| Main Fan Switch | Check continuity between switch |
|
| terminals. |
| Control Box High Limit | Terminals are normally closed, and |
| Thermostat | open at 170°F ± 5°F (76.6°C ± 2.8°C). |
| Note: Discontinued at | Check for over heating and reset |
| S/N 2011821 | thermostat. Test for proper operation. |
|
| If it will not reset and hold, replace. |
| Fuse, 1 Amp | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Step Down Transformer | 120 VAC should be present on |
|
| secondary. Replace as needed. |
| Cooling Fans | 120 VAC should now be at these fan |
|
| motors. If voltage is present, check |
|
| motors for shorts or opens. |
|
| WITH POWER OFF: Check for locked rotor. |
No automatic control | Incoming Power Supply | Check circuit breakers, reset if |
box cooling |
| required, call power company if needed |
|
| Cooling Fan Thermostat Thermostat is normally |
|
| open and closes at 120°F ± 3 (48.9°C ± 1.7°), |
|
| and opens at 100°F ± 3°F |
|
| (37.8°C ± 1.7°C). |
| Control Box Hi Limit | Terminals are normally closed, but |
| Discontinued at S/N | open at 170°C ± 5°F (76.6°C ± 2.8°C). |
| 2011821 | Check for over heating and reset |
|
| thermostat. Test for proper operation. |
|
| If it will not reset and hold, then |
|
| replace. |
| Fuse, 1 Amp | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Step Down Transformer | 120 VAC ± 10% should be present at |
|
| secondary of transformer. If proper |
|
| voltage is not present, check |
|
| transformer primary for proper |
|
| input. Replace as needed. |
26 |
| Impinger II - 1100 Series Service Manual - International |