Lincoln 1100 Series service manual Check for proper line voltage to

Models: 1100 Series

1 92
Download 92 pages 44.78 Kb
Page 28
Image 28

 

Check for proper line voltage to

 

the Burner Blower Motor. This

 

can be checked at motor connecting

 

plug terminal 2 and 5. If voltage is

 

present proceed with next step, if not,

 

wait 30 seconds, push reset button,

 

and try to restart. If this fails, check

 

wires from Thermostat and Burner

 

Blower Motor to the Ignition Control.

 

If all above fails and wires are okay,

 

replace ignition control.

Burner Blower Motor

Check for supply voltage to motor.

 

WITH POWER OFF: turn blower wheel

 

to check for locked rotor.

 

If proper supply voltage is present at

 

motor connecting plug, terminal 2

 

and 5 and motor does not run, replace motor

Air Pressure

Check for proper supply voltage

Switch

switching from “N.C.” to “N.O.” as air

(Burner Blower)

pressure switch closes.

 

If above fails, connect a temporary

 

jumper wire (FOR TESTING ONLY)

 

from terminal “C” to terminal “N.O.”

 

on ignition control (bypasses air

 

switch). NOTE: For Honeywell

 

control only.

 

Check for air switch adjustment,

 

air tube blockage, or misalignment,

 

and if these fail,replace air pressure switch

Spark Generator

A pre-purge-time of 30 to 60 seconds

 

occurs after blower motor starts, check for supply

 

voltage atspark generator.

 

If voltage is not present, check reset

 

button for the Ignition Control.

 

If voltage is still not present, replace

 

ignition control.

 

If voltage is present, visually check

 

for spark at ignitor head located in

 

burner.

Ignitor/Sensor Assembly

Check this assembly for visible

 

damage. If there is no damage, replace

 

the Spark Generator. If there is

 

damage, replace the Ignitor/Sensor

 

Assembly. Also check for frayed or

 

damaged wires in the burner tube.

Gas Valve

Gas valve should open when

 

proper supply voltage is present.

 

If no voltage is present, check the

 

reset button on the ignition

 

control, and all connections for

 

tightness. If there is still no

 

voltage present at gas valve, replace ignition

 

control.If there is voltage present, check for

 

gas pressure at the gas pressure tap

 

located in the gas piping just prior to

 

the burner. If there is no gas pressure, replace

 

gas valve

28