Lincoln 1100 Series service manual STEPPER MOTOR DRIVE Conveyor will not run

Models: 1100 Series

1 92
Download 92 pages 44.78 Kb
Page 44
Image 44

S/N 2011383 and above Temp. Display out or inaccurate S/N 2011383 and above

STEPPER MOTOR DRIVE Conveyor will not run

WITH POWER OFF:

REFER TO PAGE 45

REFER TO PAGE 33

REFER TO PAGE 45

Conveyor Switch

Check for 120 VAC to conveyor switch. If no

voltage is present, trace wiring back to the oven

power source.

 

Check conti nuity between switch terminals.

Conveyor Fuse 3AMP

Check, replace if necessary. (Not used on

 

Model 1151)

 

Fuseholder

Check, replace if necessary.

 

Conveyor Control

Check for 120 VAC supply to primary

 

(Stepper) Transformer

of transformer, if voltage is not

 

 

present, trace wiring back to the fuseholder.

 

If voltage is present, check for output voltage

 

from the transformer secondary. NOTE: This

 

control transformer outputs (2) secondary voltages.

 

Red Leads 29 VAC

 

 

Brown Leads 10 VAC

 

 

If BOTH secondary voltages are not

 

 

present, replace the transformer.

 

Speed Adjustment

This is a 0 to 50k ohm, 10 turn

 

Potentiometer

potentiometer WITH POWER OFF: remove the 3

 

pin potentiometer cable plug from the motor

 

control board. With a digital multimeter, check

 

the ohm reading across the red lead to the black

 

lead, this reading should be 50k ohms ± 5% as

 

the potentiometer is rotated through its

 

10 turn rotation. Place the meter leads

 

on the red lead and white lead. Rotating

 

the potentiometer slowly, from low to

 

 

high, the meter should show an even

 

 

transition from 0 to 50k ohms ± 5%

 

 

through the 10 turn rotation of the

 

 

potentiometer. There should be no dead

 

or open spots through the 10 turns of

 

the potentiometer. Check all three leads

 

to ground. There should be no continuity

 

to ground.

 

 

If any of the above checks fail, replace

 

the potentiometer.

 

Conveyor Motor

NOTE: if the conveyor drive motor

 

(Stepper) Control

becomes jammed, the motor will stop

 

turning. To reset, turn off conveyor

 

 

switch, wait 10 seconds and turn the

 

 

conveyor switch on.

 

If the motor does not run, check for 2 to 29 VAC across the motor terminals 1 to 2 and 3 to 5 on the conveyor motor control. If voltage is not

44

Impinger II - 1100 Series Service Manual - International

Page 44
Image 44
Lincoln 1100 Series service manual STEPPER MOTOR DRIVE Conveyor will not run