A T O N | A275 INSTALLATION MANUAL |
Triggers
A REMOTE TRIGGER IN port allows all channels to turn on or mute simultaneously. The REMOTE TRIGGER INPUT can receive 5-24 Volts AC or DC. The 12 Volt DC REMOTE TRIGGER OUT can be used to turn on other equipment, additional A275s or other amplifiers, or to perform automated functions desired by the user. Use 3.5mm mono interconnect cables to make Trigger connections.
SYSTEM TRIGGER IN
To mute/un-mute all channels simultaneously, connect a system-wide 5-24 Volt DC triggering source to the SYSTEM TRIGGER IN port using a 3.5mm mono interconnect cable. Examples of triggering sources include an ATON Multi-Zone Controller’s SYSTEM TRIGGER OUT or REMOTE OUT, an A/V receiver’s switched outlet connected to a power supply, or a +12VDC TRIGGER OUT from another ATON amplifier.
3.5mm mono interconnect cable
Figure 3-4: Remote Trigger InSYSTEM TRIGGER OUT
Whenever the A275 is powered ON, the REMOTE TRIGGER OUT becomes active. This output sends a +12VDC 100mA signal to other devices with a Trigger Input.
From AH66T
| To A275’s |
| #3-4 |
| 3.5mm mono interconnect cable |
A275 #1 | A275 #2 |
| Figure 3-5: Remote Trigger Out |
© ATON 2010 • All rights reserved. | Page 11 |