Appendix B: Rack Mounting

A275 INSTALLATION MANUAL

A T O N

Appendix B: Rack Mounting

Rack-Mount Bracket

When mounting the A275 amplifier in an equipment rack, use the included rack mount brackets for secure mounting and proper ventila- tion. The A275 requires one rack space, ensure that one rack space above and below the A275 is left open for proper ventilation.

To install the A275 into a standard 19” equipment rack:

1. Slide the rack mount kit onto the A275 chassis from the front as shown in Figure B-1.

Figure B-1

2.Ensure that the unit is flush with the front of the mounting kit. Install each of the eight screws (included) through the side mounting flanges into the holes in the sides of the unit as shown in Figure B-2. Hand tighten screws! Over-tightening could cause damage to the A275 Amplifier.

Figure B-2

 