ATTO Technology FC-42ES Celerity FC-42XS Adapter, Hardware specifications, PCI bus specifications

Models: FC-42ES FC-44ES FC-41XS FC-42XS FC-42ES, FC-44ES, FC-42XS, FC-41XS, FC-21PS, FC-22XH, FC-24XL

1 36
Download 36 pages 22.69 Kb
Page 8
Image 8
Celerity FC-42XS Adapter

Celerity FC-42XS Adapter

The dual-channel Celerity FC-42XS storage adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure.

With speeds of up to 800 MB/sec. per channel, the FC-42XS is capable of supporting the most intensive data applications, including digital content creation, tape streaming and backup, rich content delivery and complete database environments.

To ensure a smooth transition path, the FC-42XS leverages the existing Celerity FC software hardware architecture, allowing ATTO to deliver industry-leading quality and stable software architecture.

Hardware specifications

Two independent Fibre Channel ports

4-Gigabit data transfer rates per channel

800 MB/sec. maximum full-duplex throughput per channel

Supports all FC topologies: direct fabric, arbitrated loop and point-to-point

ANSI Fibre Channel: FC-PH, FC-FCP, FC FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA

Flash ROM for easy field upgrades

FC Class 3 support

Local management and diagnostics

Buffer credits: 8 @ 152 bytes; 8 @ 2k bytes

Advanced FC capabilities

Supports SNIA HBA API

On-demand automatic negotiation among 4-Gb, 2-Gb and 1-Gb Fibre Channel

Supports Target and Intitiator modes

Supports Windows FDMI and WMI

Exclusive Advanced Data Streaming (ADSTM) Technology

PCI bus specifications

64-bit, 133 MHz PCI-X

PCI-X 1.0a compliant

PCI 2.2 compliant

3.3V PCI signaling only

Environmental & physical specifications

Conforms to PCI low profile form factor standards

Length: 6.600 inches

Height: 2.536 inches

Operating Temperature: 0-45ºC (32º-113ºF)

Storage Temperature: -40º to 70ºC (-40º to 158ºF)

Relative Humidity: 5 to 95% non-condensing

5V@ 1.5A (max.)

100 lf/m (minimum) airflow recommended

External connectivity

Easy-to-install full height connection plate

External LEDs for on-line and speed status for each channel

Two optical LC SFP transceivers included

Software specifications

Windows XP, 2000, Server 2003

Red Hat Linux (2.4 and 2.6 kernel)

SUSE Linux (2.6 kernel)

Mac® OS X

3 ATTO Technology Celerity FC Storage Adapters Installation and Operation Manual