18 Stove Installation (for qualified installers only)
© Travis Industries 100-01190_000 4070326
Interior or ExteriorMasonry Chimney
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 standard.
See Chimney Connector
Requirements on page 11
for further details.
Make sure the
clean-out seals in
place.
Clay Liner
See the section "Stove
Placement Requirements" for
minimum clearances required.
Min. 18"
clearance
to ceiling This type of
installation requires
a UBC approved
masonry connector
or other method
approved by the
NFPA 211 standard.
Chimney connector sections
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section
"Floor Protection
Requirements"
Full Re-Line
(recommended)
Figure 17