Operating Your Appliance 21
© Travis Industries 100-01190_000 4070326
Bypass Operation
The bypass controls the flow of smoke inside the heater. When open, smoke goes directly up the flue,
creating more draft. When closed, the smoke goes through the combustor, utilizing the secondary
combustion system and making the heater more efficient.
When starting or re-loading the stove, open the bypass.
Once the stove reaches full temperature – typically 30 minutes, close the bypass.
The bypass handle is located on the left
side. Rotate it to open the bypass.
Bypass CLOSED
Used for normal
operation
Bypass OPEN
Used for starting
and re-loading
If the bypass does not latch in the closed position, you will need to adjust the bypass latch (see page 30).
Loading Lid Operation
Open the lid 1" for a few
seconds to allow air to
enter the firebox.
Open the bypass first (this
helps prevent smoke from
entering the room).
Lift the lid upward.
A log poker is
provided with this
stove. It attaches
with a clip to to the
back of the stove.
WARNING: This part
becomes hot - use gloves.
b
Open the air control and allow air to flow
into the firebox for 30 seconds.
cd
a
Do not wear loose clothing while re-loading the stove. Any item dangling above the opening may ignite.
Carefully close the loading lid after use. Allowing it to “slam” shut may damage the stove.