Operating Your Appliance

27

 

 

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

Problem

Possible Cause

 

 

 

 

Smoke Enters Room During

Open the bypass (pg. 21).

 

 

 

 

Start-Up

Open the air control (pg. 23).

 

 

 

 

 

Cold Air Blockage - burn a piece of newspaper to

 

 

 

 

 

establish a draft.

 

 

 

 

 

If the flame is not getting enough air, a small crack in

 

 

 

 

 

the door is all that is needed.

 

 

 

 

 

 

 

 

 

 

Kindling Does Not Start - Fire

Open the bypass (pg. 21).

 

 

 

 

Smolders

Open the air control (pg. 23).

 

 

 

 

 

Not enough starter paper - use additional newspaper if

 

 

 

 

 

necessary.

 

 

 

 

 

If the flame is not getting enough air, a small crack in

 

 

 

 

 

the door is all that is needed.

 

 

 

 

 

 

 

 

 

 

Smoke Enters Room While Re-

Open the bypass before opening the door (pg. 21).

 

 

 

 

Loading

Open the air control before opening the door (pg. 23).

 

 

 

 

 

Open the loading lid 1 inch and let air enter the firebox

 

 

 

 

 

for a few seconds. Once the smoke appears to be

 

 

 

 

 

flowing up the chimney consistently, open the loading

 

 

 

 

 

lid completely.

 

 

 

 

 

Insufficient Draft - Chimney height and outside

 

 

 

 

 

conditions can negatively affect draft. In these cases a

 

 

 

 

 

small amount of smoke may enter the home. Adding

 

 

 

 

 

more pipe or a draft-inducing cap may help.

 

 

 

 

 

 

 

 

 

 

Stove Does Not Burn Hot Enough

Wood is Wet - see the section "Selecting Wood" on

 

 

 

 

 

page 26 for details on wood.

 

 

 

 

 

Make sure the air control is all the way open. Slide the

 

 

 

 

 

control back and forth to insure the control is not stuck.

 

 

 

 

 

Insufficient Draft - Chimney height and outside

 

 

 

 

 

conditions can negatively affect draft. In these cases

 

 

 

 

 

the fire may burn slowly. Adding more pipe or a draft-

 

 

 

 

 

inducing cap may help.

 

 

 

 

 

 

 

 

 

 

Blower Does Not Run

Stove is Not Up to Temperature - This is normal. The

 

 

 

 

 

blower will come on when the stove is hot - usually 15

 

 

 

 

 

to 30 minutes.

 

 

 

 

 

Electricity is Cut to the Blower - Check the household

 

 

 

 

 

breaker or fuse to make sure it is operable.

 

 

 

 

 

 

 

 

 

 

Stove Does Not Burn Long

Depending upon wood, draft, and other factors, the

 

 

 

 

Enough

burn time may be shorter then stated. Make sure the

 

 

 

 

doors are sealing and not allowing air into the firebox -

 

 

 

 

 

 

 

 

 

 

See the section "Door and Glass Inspection" on page

 

 

 

 

 

29 for details.

 

 

 

 

 

Check the ash bed for coals. Often, coals are still

 

 

 

 

 

glowing under a slight bed of flyash. By raking these

 

 

 

 

 

into a pile you can re-start your stove quickly.

 

 

 

 

 

 

 

 

© Travis Industries

100-01190_000

4070326

Page 27
Image 27
Avalon Stoves Arbor owner manual Troubleshooting

Arbor specifications

The Avalon Stoves Arbor is an exceptional addition to modern home heating solutions, blending efficiency, aesthetics, and advanced technology. Designed for those who appreciate both functionality and style, the Arbor model is a wood-burning stove that provides an impressive heat output while keeping environmental impacts in check.

One of the standout features of the Avalon Arbor is its remarkable heating capacity. It can efficiently heat spaces up to 2,000 square feet, making it an excellent choice for larger homes or open floor plans. This makes it a perfect solution for homeowners looking to reduce their heating bills without sacrificing comfort. The Arbor’s large firebox is designed to hold logs up to 18 inches long, allowing for extended burn times and fewer reloads throughout the day.

The stove is engineered with a clean-burning technology that maximizes efficiency while minimizing emissions. This is achieved through the unique air wash system, which helps keep the glass door clean and clear, providing an unobstructed view of the beautiful flames. The EPA-certified design ensures that the stove meets strict emissions guidelines, making it an environmentally friendly option for home heating.

In terms of design, the Avalon Arbor features a sleek and contemporary look that can seamlessly fit into various interior styles. With its large glass door and available finishes, including black, porcelain enamel, and stone, the Arbor allows homeowners to choose a look that complements their décor. Its sturdy construction from quality materials ensures durability and longevity, enhancing its appeal as a long-term investment.

Moreover, the Arbor stove incorporates advanced features such as an adjustable air control system. This allows users to easily regulate the burn rate and heat output according to their preferences, ultimately resulting in greater comfort and efficiency. The optional blower fans elevate the stove’s heating efficiency by circulating warm air throughout the room, further enhancing its performance in larger spaces.

Overall, the Avalon Stoves Arbor is a perfect fusion of form and function, ideal for those seeking an efficient wood-burning stove without compromising on style or environmental responsibility. With its powerful heating capabilities, clean-burning technology, and attractive design, the Arbor remains a top choice for homeowners looking to enhance their living spaces. Whether for a cozy living room or an expansive great room, the Avalon Arbor provides warmth and ambiance, making it a valuable addition to any home.