36 Optional Equipment
© Travis Industries 100-01190_000 4070326

Rear Blower Installation (Part # 99000138)

The rear blower improves heat transfer by pushing heated air through the convection channel. Operating
instructions are described in the section "Blower Operation".
Route the wires on the
outside of the stove, behind
the convection jacket.
d
e
Tuck the thermodisk into place. It
wedges between the rear heat sheild
and the cast iron firebox.
Bend the legs of the
thermodisk bracket to
make it 1-1/2 deep.
1-1/2
a
3/8" Wrench
gPlug the blower in. Do not route the power cord under or over the stove or in a
location where it may become damaged.
b
c
Route the wires from the blower through the hole
in the back of the blower housing. Attach these
wires to the thermodisk wires.
Position the blower near the rear of the stove. Tuck all excess wire into the
blower box, making sure it does not contact any moving parts. Make sure when
installing the blower, these wires do not become loose.
Attach the blower to the
stove with the three screws
included with the blower.
f