Installing a New System IP401 Compact Office Wall Mounting - Page 43
IP401 Compact Office Wall Mounting
Bath variants of the IP401 Compact Office can be wall mounted. Four retaining slots (item n below)
enable the IP401 unit to be mounted in any one of three positions (two horizontal and one vertical) by
using two No. 8 Panhead screws. A Z-bracket (item o below, supplied with unit) is used to retain the
IP401 unit in position.
Cautions: 1. The Z-bracket must not be used as the sole wall mounting fixture.
2. The weight of the IP401 unit must be held by the two No 8 Panhead screws located
into the retaining slots.
3. When mounted vertically, the air vents (on the rear panel of the IP401 unit) must be
on the top surface. E.g. item o below must be fitted above the unit.
Procedure:
1. Drill two holes 16cm apart (horizontally or vertically – see Caution 3 above).
Using suitable wall fixings (wall plugs), insert two No.8, Panhead screws (25mm long min. - not
supplied) into wall leaving approximately 1cm proud of wall.
2. Fit the Z-bracket (item o below) onto the base of the unit using the M3 Plastite self tapping screw
supplied.
3. Slide the IP401 Compact Office unit onto the two screws, locating them into the two retaining slots
(item n below).
4. Mark the position of the retaining screw (No. 8 Panhead or similar – not supplied) that is to be
used through the slot of the Z-bracket .
5. Remove the unit from the wall and, using suitable wall fixings, drill a hole for the Z-bracket
retaining screw.
6. Re-position the IP401 compact Office unit and secure with a No. 8 Panhead (or similar) through
the slot of the Z-bracket.
IP Office Installation Manual Installing a New System - Page 43
40DHB0002USCL – Issue 7 (09/25/2002) IP401 Compact Office Wall Mounting