Power up

Power up

Avaya P330 AC Version

1.Insert the power cord into the power connector (BUPS or Power Supply) on the rear of the unit.

BUPS connector

AC connector Avaya P330 AC Version

2.Insert the other end of the power cord into the electricity supply or the BUPS connector.

!The unit powers up and performs a self test procedure. The LEDs flash at regular intervals after the self-test procedure is completed successfully.

3 Avaya P330 DC Version

WARNING: Before performing any of the following procedures, ensure that DC power is OFF.

CAUTION: This product is intended for installation in restricted access areas and is approved for use with 18 AWG copper conductors only. The installation must comply with all applicable codes.

DC terminal block

1.Connect the power cable to the switch at the input terminal block on the rear of the unit.

!The terminals are marked “+”, “-“ and the IEC 5019a Ground symbol.

!The size of the three screws in the terminal block is M3.5.

!The pitch between each screw is 9.5mm.

2.Attach the appropriate lugs at the wire end of the power supply cord.

3.Wire the DC power supply to the terminal block.

!The unit powers up and performs a self test procedure. The LEDs flash at regular intervals after the self-test procedure is completed successfully.

WARNING: The proper wiring sequence is:

ground to ground

positive to positive

negative to negative

Always connect the ground wire first and disconnect it last.