Appendices 47

Appendices

Appendix A: FLASH Upgrades

OutLook Firmware Upgrade Instructions

You can update the firmware of your OutLook switch by using a special update utility provided by Avocent. This utility automatically configures the port communications settings to allow direct downloading from the connected server.

To update your firmware, you need the following items:

Computer running Windows NT, Windows 95, Windows 98 or Windows 2000

Available serial port (COM port) on the server

Standard serial cable (DB-male) that connects the switch and the server

Firmware update

To update firmware:

1.Connect the standard serial cable to a COM port on the server and to the serial connector on the back panel of the switch. Make a note of which COM port you have chosen, then turn on the switch.

2.Go to http://www.avocent.com/support and click on Downloads to access the firmware update file. Once the download is complete, navigate to the drive where you have saved the firmware update and unzip the file.

3.Double-click to run the file WUpDate.exe.

4.In the dialog box that displays, select the desired language and COM port.

5.Click Load.

6.Once the firmware is updated, the following message displays: Download complete. Click Done to exit the dialog box.

7.The switch automatically reboots after the update is completed.

Possible error conditions

If the download does not execute properly, verify the following:

Verify that the COM port is correct.

Verify that no other program is currently using the COM port, or that a previous DOS window/shell is open that had used the desired COM port.

Verify that no other copies of the WUpDate utility are currently running.

Verify that a straight through (1-to-1) type of serial cable is used, not a null modem serial cable.

Verify in the selected COM port’s Advanced Port settings that the FIFO buffers are selected and that the receive buffer is set to High.

WARNING: While upgrading, do not use your computer for anything else or switch between windows. Close all other windows if necessary. If the update was unsuccessful (such as during a power outage), repeat the procedure.