62CCM840/1640 Installer/User Guide

Server CLI Command Parameters (Continued)

Parameter

Description

CHAR=^<char>

CLI access character in the range A through _ (underscore). (The

 

allowable ASCII range is Øx41-Øx5F and Øx61-Øx7A.) The CLI

 

access character, when pressed simultaneously with the Ctrl key

 

during a session with an attached serial device, will suspend the

 

session with the device and place you in CLI command mode.

 

This value will be used if a port’s Port Set command contains a

 

Char=None parameter.

 

Default = ^d is the manufacturing default

 

 

CONNECT=ONOFF

Enables or disables the ability to use the Connect command from

 

the serial CLI port. When enabled, a serial CLI user may use the

 

Connect command to establish a connection to the serial device

 

attached to another CCM serial port. When disabled, you cannot

 

use the Connect command from the serial CLI port.

 

Default = ON

 

 

HISTORY=

Port history file processing options during connection (Hold or Auto)

HOLDAUTO,

and when a session ends (Clear or Keep):

CLEARKEEP

When Hold is specified, upon connection you are informed of how

 

much data is in the history buffer, but the data is not displayed.

 

When Auto is specified, upon connection you are informed of how

 

much data is in the history buffer, and it is then displayed.

 

When Clear is specified, the history buffer’s content is cleared when

 

a session ends.

 

When Keep is specified, the history buffer’s content is retained

 

when a session ends. You cannot specify both Clear and Keep or

 

both Hold and Auto.

 

Default = HOLD,CLEAR

 

 

MODEMINIT=

Modem initialization string, enclosed in quotation marks. Must

“<string>”

contain at least ATV1 and SØ=1.

 

Default = “” (no modem is attached to serial CLI port)

 

 

TIMEOUT=<time-out>

Number of time-out minutes in the range Ø-90. If no data is received

 

or transmitted during a Telnet session for the specified period, the

 

session will time-out. A zero value indicates no time-out. This value is

 

used for any CCM port that does not have a time-out value set with

 

the Port Set command, during a Telnet session to port 23 or an SSH

 

session to port 22.

 

Default = 15 minutes is the manufacturing default

 

 

Server FLASH command

The Server FLASH command updates the CCM program images in FLASH memory. You may wish to use this command to update the program with new features or to install a later release of the program.

There are two program images that you may update in the CCM FLASH. The boot image file (ccm40bt.img) contains the CCM startup and self-test logic. The application image (ccm40app.img) contains the CCM program that provides CCM functionality.