Axis Communications Q1614-E Ports & Devices, Maintenance, I/O Ports, COM Port, Port Status

Models: Q1614-E

1 71
Download 71 pages 9.71 Kb
Page 58
Image 58
Ports & Devices

AXIS Q1614-E Network Camera

System Options

Ports & Devices

I/O Ports

The Axis product provides two configurable input and output ports for connection of external devices. For information about how to connect external devices, see Connectors on page 68.

The I/O ports are configured under System Options > Ports & Devices > I/O Ports. Select the port direction (Input or Output). The ports can be given descriptive names and their Normal states can be configured as Open circuit or Grounded circuit.

COM Port

The Axis product has one RS-485/RS-422 serial port. The port supports the following modes:

Generic HTTP allows the Axis product to receive data and send commands via HTTP.

Pan Tilt Zoom is used to control a PTZ device. The PTZ device requires a driver. See Install PTZ Driver for more information. Drivers can be downloaded from www.axis.com

Generic TCP/IPallows the Axis product to receive data and send commands via TCP/IP. Daisy chain server - Allows Daisy chain clients to communicate with the Axis product.

Select the desired Port Type from the drop-down list. For more information on Serial Port Settings and Daisy Chain Port Settings

see the online help I/O Ports.

Port Status

The list on the System Options > Ports & Devices > Port Status page shows the status of the product’s input and output ports.

Accelerometer

The leveling assistant that helps to level the camera is enabled by default. To disable it, de-select the Enable leveling assistant option from System Options > Ports & Devices > Accelerometer and click Save. To refresh the page and view the saved setting, click Reset.

Maintenance

The Axis product provides several maintenance functions. These are available under System Options > Maintenance.

Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current settings.

Note

A restart clears all entries in the Server Report.

Click Restore to reset most settings to the factory default values. The following settings are not affected:

the boot protocol (DHCP or static)

the static IP address

the default router

the subnet mask

the system time

the IEEE 802.1X settings

the focus position