Documentation Number 232MSS2-0108 Manual 15
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445
Enter Port Address [02F8]:
Enter Baud Rate ( 1 = 150 2 = 300 3 = 600
4 = 1200 5 = 2400 6 = 4800
7 = 9600 8 = 19200) [7]:
Enter Parity (0 = No 1 = Odd 2 = Even) [0]:
Enter Number of Data Bits ( 7 = Seven Data Bits
8 = Eight Data Bits) [8]:
Enter Smart Switch Second Char (Decimal Value) [2]:
Enter Hot Key Sequence (1 = <LftShift><Alt><A|B|C|D|N>
2 = <Rht Shift><Alt><A|B|C|D|N>
3 = <Lft Shift><Alt><1|2|3|4|N>
4 = <Rht Shift><Alt><1|2|3|4|N>
5 = <CTRL><ALT><A|B|C|D|N>
6 =<CTRL><ALT><1|2|3|4|N>)[1]:
At this point a file called GO.BAT will be created.
Type GO and press the ENTER key.
Once the GO.BAT file is created, every time you wish to begin
the SSTSR all that you need to do is type GO and press the ENTER
key. If you need to change any of the settings of the SSTSR simply
run the SETUP.EXE program again to create a new GO.BAT file.
2) SSTSR.EXE Method
The SSTSR.EXE method requires the same parameters (for a
description refer to the Parameters section) as the SETUP.EXE
method, except that they are all specified through the command line.
Each of these parameters begins with a command symbol followed
by an option as defined in the following table.
Command Description Options
A or a Port Address Hexadecimal Address (0 - FFFFh)
B or b Baud Rate 1 = 150 2 = 300 3 = 600
4 = 1200 5 = 2400 6 = 4800
7 = 9600 8 = 19200
D or d Number of Data Bits 7 = 7 Data Bits 8 = 8 Data Bits
P or p Parity 0 = No 1 = Odd 2 = Even
U or u User Defined Char. Decimal (0 - 255)
H or h Hot Key 1 = <Left Shift><ALT><A|B|C|D|N>
2 = <Right Shift><ALT><A|B|C|D|N>
3 = <Left Shift><ALT><1|2|3|4|N>
4 = <Right Shift><ALT><1|2|3|4|N>
5 = <CTRL><ALT><A|B|C|D|N>
6 = <CTRL><ALT><1|2|3|4|N>