Table 3. DTE MASTER PORT CHART
Master Port |
| A,B,C & D Ports | |||
| (DTE) | Signal |
| (DCE) | |
Pin# |
| Direction | Description | Pin# | Direction |
2 |
| Output | Transmit Data (TD) | 3 | Input |
3 |
| Input | Receive Data (RD) | 2 | Output |
4 |
| Output | Request to Send (RTS) | 7 | Input |
5 |
| Input | Clear to Send (CTS) | 8 | Output |
7 |
| Signal Ground (SG) | 5 |
The 232MSS2 supports the following
NOTE: Handshake lines DSR and DTR are tied together on each connector and are not passed through to the master port. All other lines are not connected.
The Mini Smart Switch selects port A as the default port at power
up.
Serial Data Configuration
In order for the host device that is connected to the master port to select any of the four ports, the Mini Smart Switch must be set to match the host's communication format. Dipswitch “SW1” is used to select the communication format of the Mini Smart Switch. Switch positions 1 through 3 select the baud rate. Switch position 5 selects 7 or 8 data bits. Switch position 6 determines if parity is enabled or disabled.
NOTE: A data format of 7 data bits, no parity and one stop is not allowed.
Switch position 8 selects the port configuration, see section titled "Port Configuration". Refer to Table 1. Always power down the smart switch when changing switch settings.
Smart Switch Operation
Smart Switch mode is selected when dipswitch “SW1” position 7 is “Off.” In Smart Switch mode, the 232MSS2 is constantly looking for the three character preamble code by monitoring the data that is being received on the master port from the host device. The 232MSS2 requires a three character preamble code to turn on and off a port. The first character must be the ASCII escape character (decimal 27). The second character is user programmable by setting dipswitch “SW2”. “SW2” comes from the factory programmed to the
Documentation Number | 5 |
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353