Power Supply Connections

The 232OPSDA requires an isolated external power supply that is able to produce 9-16VDC @10mA in addition to the port power. The positive(+) lead of the power supply is connected to the terminal block labeled +12VDC and the negative(-) lead is connected to the terminal block labeled GND. The external power supply powers the I/O side of the module. The RS-232 side of the module is port powered using RTS and DTR. These lines may be either LOW or HIGH to provide power to the module. The two sources of power are required for optical isolation.

Documentation Number 232OPSDA1397 Manual

9

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5105