Table 2.2 - RS-232 Connector Pinout

 

 

Signal

 

DB-25S

 

Direction at

 

Pin #

Signal

232SDD16

Notes

 

 

 

 

2

Transmit Data (TD)

Input

Connection is required.

3

Receive Data (RD)

Output

Connection is required.

4

Request to Send

Input

May be used to power

 

(RTS)

 

unit if kept high.

7

Signal Ground (SG)

 

Connection is required.

20

Data Terminal

Input

May be used to power

 

Ready (DTR)

 

unit if kept high.

Table 2.3 - 232SDD16 To DTE Connections

232SDD1

 

DTE DB-

DTE DB-9

6 Pin #

Signal

25

Connection

 

 

Connection

 

 

 

 

 

2

Transmit Data (TD)

2

3

3

Receive Data (RD)

3

2

4

Request to Send (RTS)

4

7

7

Signal Ground (SG)

7

5

20

Data Terminal Ready (DTR)

20

4

Table 2.4 - 232SDD16 To DCE Connections

232SDD16

 

DCE DB-25

DCE DB-9

Pin #

Signal

Connection

Connection

 

 

 

 

2

Transmit Data (TD)

3

2

3

Receive Data (RD)

2

3

4

Request to Send (RTS)

5

8

7

Signal Ground (SG)

7

5

20

Data Terminal Ready

6

6

 

(DTR)

 

 

232SDD16-1005 Manual

7

Power Supply Connections

Power to the 232SDD16 can be supplied by the RS-232 serial port handshake lines (RTS, DTR) or by an external power supply through the 2.5mm power jack or from the I/O connector. Most serial ports can provide enough power to supply the 232SDD16’s 15 milliamp requirement. If you plan to use this method to power the unit, your software must set the RS-232 RTS and DTR lines to the high state. An external power supply must be able to supply 8 to 16 Vdc at 35ma.

NOTE: Power requirements of the module does not include the power consumption of any external devices connected to the module. Therefore, any current that is sourced by the digital outputs must be added to this value and the current must not exceed the maximum output source current. Refer to the 232SDD16 Specification Section of this manual.

8

232SDD16-1005 Manual

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

PH (815) 433-5100 -- FAX (815) 433-5104

Page 6
Image 6
B&B Electronics manual RS-232 Connector Pinout, 232SDD16 To DTE Connections, 232SDD16 To DCE Connections