SPECIFICATIONS

“A” AND “B” SUPPLIES

Output Voltage Range:

0V to 24VDC (0 ± 100mV)

Output Current Limit Range:

0 to 0.5A.

Constant Voltage Operation:

Voltage Regulation:

 

Load:

≤0.01% + 3mV

Line (108 – 132V):

≤0.01% + 3mV

Ripple Noise:

≤2mVrms (5Hz to 1MHz)

Recovery Time:

≤100us typical.

Temp. Coefficient

 

0°C to 40°C

≤300ppm/°C

Tracking Error:

 

No Load:

≤0.2% + 20mV

Full Load:

≤0.2% + 100mV

Constant Current Operation:

 

Adjustable Current Limits:

≤30mA to ≥500mA

Current Regulation:

 

Load:

≤0.2% + 6mA.

Line (108 – 132V):

≤0.2% + 3mA.

Ripple Current and Noise:

≤3mA rms.

Metering (“A” & “B” only):

 

Voltmeter:

 

Range:

0 to 25V

Accuracy:

≤2.5% of Full Scale

 

±2% + 2 digits

 

(1652)

Ampmeter:

 

Range:

0 to 600mA

Accuracy:

≤2.5% of Full Scale

 

±2% + 2 digits

 

(1652)

5

Page 9
Image 9
B&K 1652, 1651A instruction manual Specifications, B Supplies