1-15HP Size A and B Controls

(For all 15H Inverter, 18H Vector, and 23H Servo).

Single Expansion Board Installation

Procedure:

1.Be sure drive operation is terminated and secured.

2.Remove all power sources from the control.

3.Wait at least 5 minutes for internal capacitors to discharge.

4.Remove the four (4) Phillips head screws that secure the control cover.

5.Remove the control cover.

6.Remove the #6 screw at position MH1 (upper left on the main circuit board. See Figure 3-1.

7.Install the long standoffs provided in the installation hardware as shown in Figure 3-1. (Be sure the Male/Female standoff is at position MH1. The other three are Female/Female.)

8.Slide the expansion board male connector into the female connector of the control board.

9.Securely mount the expansion board to the standoffs installed in step 7 using #6 screws provided in the installation hardware. See Figure 3-2.

10.The mechanical installation of the expansion board is now complete. Refer to Section 4 of this manual and configure the jumpers as desired. Also complete the wiring before you proceed to step 11.

11.When complete, install the control cover using the four (4) Phillips head screws.

12.Restore all power sources to the control.

13.Restore drive operation.

3-2 Installation