SureCross Plug-and-Play: Configured Kits

One box houses the preset Gateway, Node(s), accessories and hardware to get you up and running quickly.
The Gateway is configured to independently control I/O mapping for all devices within the kit.
Network traits are preset to provide discrete I/O on change of state and periodic reporting of analog I/O.
22 More information online at bannerengineering.com
OFF
To
Control
Valve
DX80
Node
10-30V DC

3 miles

DX80
Node
DX81
Battery
Module
Flow
Sensor
10-30V DC
DX80
Gateway

3 miles

Model Number Frequency Icon* Gateway I/O Node 1 I/O Node 2 I/O Node 3 I/O Node 4 I/O Data Sheet
DX80K9M6DP1 900 MHz GN
Modbus Enabled
Discrete
4 IN & 4 OUT
Discrete
4 IN & 4 OUT 129306
DX80K2M6DP1 2.4 GHz GN
DX80K9M6DP4 900 MHz GN
N
N
NDiscrete
4 IN & 4 OUT
Discrete
1 IN & 1 OUT
Discrete
1 IN & 1 OUT
Discrete
1 IN & 1 OUT
Discrete
1 IN & 1 OUT 129308
DX80K2M6DP4 2.4 GHz GN
N
N
N
Model Number Frequency Icon* Gateway I/O Node 1 I/O Node 2 I/O Data Sheet
DX80K9M6MP1 900 MHz GN
Modbus Enabled
Discrete
2 IN & 2 OUT
Analog
2 IN & 2 OUT
Discrete
2 IN & 2 OUT
Analog
2 IN & 2 OUT
129312
DX80K2M6MP1 2.4 GHz GN
DX80K9M6MP2 900 MHz GNN Discrete
2 IN & 2 OUT
Analog
2 IN & 2 OUT
Discrete
1 IN & 1 OUT
Analog
1 IN & 1 OUT
Discrete
1 IN & 1 OUT
Analog
1 IN & 1 OUT
129313
DX80K9M6MP2 2.4 GHz GNN
Analog &
Discrete
Flex
Power
Systems
ENGINEERED APPLICATIONS
SureCross™ Unlimited Solutions
This application employs a congurable Gateway, a FlexPower Node and a 10 to 30V dc Node. The Gateway provides two functions: rst to
determine the appropriate valve control actuation and second, to extend transmission range for the application up to 6 miles. The FlexPower
Node is located in a remote location without access to power and cycles periodically to collect ow data for media. Based on this data, the
Gateway dictates the open and close action of the valve to the output on the 10 to 30V dc Node, which is located on the valve.
Model Number Frequency Icon* Gateway I/O Node 1 I/O No tes Data Sheet
DX80K9M3PE1 900 MHz GN
Modbus Enabled
Discrete
2 OUT
(sinking)
Discrete
1 IN
(FlexPower™ supply
configured for MINI-BEAM)
1 IN
(passive)
DX81
Flex
Power supply
included; provides power
for
Flex
Power Node and
MINI-BEAM
129318
DX80K2M3PE1 2.4 GHz GN
DX80K9M3GE1 900 MHz GNDiscrete
2 OUT
(sinking)
Analog
2 OUT
(0-20 mA)
Discrete
2 IN (passive)
Analog
1 IN
(1
Flex
Power supply
configured to provide 15V for
500 ms every 15 minutes)
1 IN
(passive)
DX81
Flex
Power supply
included; provides power
for
Flex
Power Node and
one analog sensor
129320
DX80K2M3GE1 2.4 GHz GN
* = Gateway = Node † = Discrete outputs are sourcing unless otherwise noted. Analog outputs are 0-20 mA.
GN
Discrete
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com