SureCrossPlug-and-Play: Configured Kits

One box houses the preset Gateway, Node(s), accessories and hardware to get you up and running quickly.

The Gateway is configured to independently control I/O mapping for all devices within the kit.

Network traits are preset to provide discrete I/O on change of state and periodic reporting of analog I/O.

Discrete

Model Number

Frequency

 

Icon*

 

DX80K9M6DP1

900 MHz

G

N

 

 

 

 

 

 

DX80K2M6DP1

2.4 GHz

G

N

 

DX80K9M6DP4

900 MHz

G

NNNN

 

DX80K2M6DP4

2.4 GHz

G

NNNN

Modbus Enabled

Gateway I/O

Discrete

4 IN & 4 OUT

Discrete

4 IN & 4 OUT

Node 1 I/O

Node 2 I/O

Node 3 I/O

Node 4 I/O Data Sheet

Discrete

 

 

 

129306

4 IN & 4 OUT

 

 

 

 

 

 

 

Discrete

Discrete

Discrete

Discrete

129308

1 IN & 1 OUT

1 IN & 1 OUT

1 IN & 1 OUT

1 IN & 1 OUT

 

 

 

 

 

 

Analog &

Model Number

 

Frequency

 

 

Icon*

Discrete

DX80K9M6MP1

 

900 MHz

 

G

N

 

 

 

 

 

 

DX80K2M6MP1

 

2.4 GHz

 

G

N

 

 

 

 

DX80K9M6MP2

 

900 MHz

 

G

N N

 

DX80K9M6MP2

 

2.4 GHz

 

G

N N

 

 

 

FlexPower

Model Number

 

Frequency

 

 

Icon*

 

 

 

Systems

DX80K9M3PE1

 

900 MHz

 

G

N

 

 

 

 

 

 

DX80K2M3PE1

 

2.4 GHz

 

G

N

 

 

 

 

DX80K9M3GE1

 

900 MHz

 

G

N

 

DX80K2M3GE1

 

2.4 GHz

 

 

G

N

 

 

 

 

 

 

 

 

 

 

 

 

Modbus Enabled

Modbus Enabled

Gateway I/O

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

Gateway I/O

Discrete

2OUT

(sinking)

Discrete

2OUT

(sinking)

Analog

2OUT

(0-20 mA)

Node 1 I/O

Discrete

2 IN & 2 OUT

Analog

2 IN & 2 OUT

Discrete

1 IN & 1 OUT

Analog

1 IN & 1 OUT

Node 1 I/O

Discrete

1 IN

(FlexPower™ supply

configured for MINI-BEAM)

1IN

(passive)

Discrete

2 IN (passive)

Analog

1 IN

(1 FlexPower supply

configured to provide 15V for

500 ms every 15 minutes)

1IN

(passive)

Node 2 I/O

Data Sheet

 

129312

Discrete

 

1 IN & 1 OUT

129313

Analog

 

1 IN & 1 OUT

 

 

 

Notes

Data Sheet

DX81 FlexPower supply

 

included; provides power

129318

for FlexPower Node and

 

MINI-BEAM

 

DX81 FlexPower supply

 

included; provides power

129320

for FlexPower Node and

 

one analog sensor

 

* G = Gateway

N = Node

† = Discrete outputs are sourcing unless otherwise noted. Analog outputs are 0-20 mA.

ENGINEEREDSureCross™ Unlimited SolutionsAPPLICATIONS

This application employs a configurable Gateway, a FlexPower Node and a 10 to 30V dc Node. The Gateway provides two functions: first to determine the appropriate valve control actuation and second, to extend transmission range for the application up to 6 miles. The FlexPower Node is located in a remote location without access to power and cycles periodically to collect flow data for media. Based on this data, the Gateway dictates the open and close action of the valve to the output on the 10 to 30V dc Node, which is located on the valve.

3 miles

3 miles

F l o w

S e n s o r

 

 

 

 

DX81

To

D X 8 0

DX80

DX80

Battery

N o d e

Gateway

Node

Module

C o n t r o l

 

 

 

 

Va l v e

 

 

 

 

O F F

10 - 30V DC

10 - 30V DC

22

More information online at bannerengineering.com

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 22
Image 22
Banner American Products Wireless Network manual SureCross Plug-and-Play Configured Kits, Discrete†, Analog, Systems