3)Program 2 Out Analog

båÅçêÉ=smñ=fåëí~ää~íáçå=dìáÇÉ

VPx Hardware

3)Program 2 Out Analog

One 15-pin D connector is provided for the Analog Program 2 Output. This output is identical to the analog Program 1 Output, except that it does not include edge feathering and data doubling components.

4)Program 2 Out DVI

One DVI connector is provided for the Digital Program 2 Output. This output is identical to the digital Program 1 Output, except that it does not include edge feathering and data doubling components.

5)Program 1 Out DVI

One DVI connector is provided for the Digital Program 1 Output. This output includes all edge feathering and data doubling components, and is designed for a digital connection to your projector.

6)Program 1 Out Analog

One 15-pin D connector is provided for the Analog Program 1 Output. This output includes all edge feathering and data doubling components, and is designed for an analog connection to your projector.

7)Program Out HD/SDI

One BNC connector is provided for the HD/SDI (High Definition/Serial Digital Interface) output. Refer to the “Program Output Notes” section on page 14 for additional information on video outputs.

8)Program Link Out

One DVI connector is provided for the Program Link Output. To ensure proper data doubling in wide screen configurations, this output connects to the Program Link Input on another VPx.

9)Program Link In

One DVI connector is provided for the Program Link Input. To ensure proper data doubling in wide screen configurations, this input connects to the Program Link Output from another VP (or VPx).

Note

10) Ethernet Port

In Chapter 3 “Installation” of the Encore Presentation System User’s Guide, refer to the “Program and Source Link Connections” section for details on the link connectors in wide screen configurations.

One RJ-45 connector is provided for 10/100BaseT Ethernet communications. For multiple connections, use an Ethernet switch on an isolated network.

11) M/E 1 Connectors

12) M/E 2 Connectors

13) M/E 3 Connectors

Six analog and digital connectors are provided for each M/E. Please note:

~All M/E boards are identical on a VPx. See the “VPx M/E Connectors” section on page 12 for details.

~Refer to the “M/E Connector Priority” section on page 13 for important information on connector priority.