For this procedure, you will need:

Table 5.

Equipment List, Wide Screen Stack Configuration

 

 

 

 

Qty.

 

Item

Note

2

 

VP

Master units (ID#1 and ID#2) must be VP, not VPx.

 

 

 

 

2

 

VP or VPx

The ID of the bottom stack processor must always be lower than the ID

 

 

 

of the top stack processor. Use 6 total processors for triple wide

 

 

 

screen, use 8 for quadruple wide, etc.

1

 

Controller

Model LC only

 

 

 

 

2

 

Video Projectors

Customer supplied

 

 

 

 

4

 

DVI or Analog Monitors

Program and Preview (customer supplied)

 

 

 

 

1

 

Ethernet Switch

Customer supplied

 

 

 

 

5

 

Ethernet cables

Customer supplied. Additional cables required for routers.

 

 

 

 

TBD

 

Program Link Cables

Use 2 for double wide screen application, left justification

 

 

 

 

 

 

 

Use 4 for triple wide screen application, left justification

 

 

 

 

 

 

 

Use 4 for double wide screen application, center justification

 

 

 

 

 

 

 

Use 6 for triple wide screen application, center justification

 

 

 

 

TDB

 

Source Link Cables

Minimum 4 for double wide screen application.

 

 

 

 

TBD

 

Sources, routers, cables

Analog, Video and/or DVI as required (customer supplied)

„Use the following steps to install a wide screen “stack” configuration:

Important

It is recommended that each stack consists of two “fully loaded” processors, each with three M/Es. If necessary, you can use a mis-matched configuration (e.g., two M/Es in the bottom stack, three in the top), but the top stack must always have three M/Es installed. In this way, your stacked set will never have anything less than four M/Es available.

1.Software Version — Prior to connecting your VPx processor(s), ensure that software version 1.22 (or higher) is installed in your Encore Controller. Refer to Appendix C, “Upgrading Software” in the Encore Presentation System User’s Guide for complete upgrade instructions.

2.Follow the unpacking procedures as listed in the “Unpacking and Inspection” section on page 15.

3.Refer to the “Technical Specifications” section on page 28 for electrical and mechanical details.

4.Refer to the “VPx Hardware” section on page 8 for all connector locations.

5.For each VPx, follow the rack mount procedures as outlined in the Rack-Mount Installation” section on page 15.

Important

Remember that master units (ID#1 and ID#2) must be VP, not VPx. “Slave” units can be VP or VPx.