4. Connections
Although this is a standard analog RGBHV output, it is only meant to be used by another Solaris displays.
Theoutput signals are not CRT-compatible, so they may not displaycorrectly on a standard monitor
4.4 Communication Connections4.4.1 RS232 IN/OUT
What can be connected to theRS232 IN connection ?
TheRS232 IN connection allows the Solaris LC40 to comm unicate with a computer e.g. IBM PC or Apple Macintosh.
RS232IN
Control PC
RS232
RS232IN RS232OUT
Image4-13
RS232connection
Applications of the RS232 connection
Remote control:
• easyadjustment of LCD panel via IBM PC (or compatible) or MAC connection.
• RS232 address range from 0 to 255.
• allowstora ge of multiple LCD panel configurations and set ups.
• wide range of control possibilities.
RS232 OUT
Tomake a loop through connection with other Solaris LC40’s.
4.5 Cable coverWhy cable cover
With the cable cover,all connections are protected to be discon nected.
Mounting the cable cover.
1. Slide the cover over the connections.
2. Push the cover hooks into the holes. (image 4-14)
3. Slide the cover to the right.
4. Fix this position by turning in the screw on the left side.
R5976672 SOLARISLC40 13/01/2005 25