Beckett 7600WTM manual Installation, Initial Set-up, How to open WTS

Models: 7600WTM

1 12
Download 12 pages 52.54 Kb
Page 5
Image 5
Figure 3 - How to open WTS

Figure 3 - How to open WTS

Installation

Risk of Fire, Explosion, and

Burn Hazard.

yDo not attempt to recharge, disassemble, heat above 85°C, expose to water, puncture, incinerate, or short- circuit the battery.

yKeep battery out of reach of children and in original package until ready to use.

yMount with battery at bottom position only. Failure to do so could expose the battery to water.

yDispose of used batteries promptly.

Initial Set-up

1.Remove power from the AquaSmart.

2.Snap the AquaSmart Wireless Module (AWM) onto the COM Port (Figure 2) on the side of the AquaSmart boiler temperature control. Restore power to the AquaSmart control.

3.Remove the internal cartridge containing the

battery cell from the Wireless Temperature Sensor (WTS). Press in the plastic tabs and pull the cartridge out as shown in Figure 3.

4.Remove the plastic insert on the battery terminal. Make sure battery is inserted properly (see polarity mark on battery holder).

5.Mount the WTS with the two screws provided at your desired location. Mount the sensor on any exterior wall (preferably on the north face of the house), at least 6 inches below any vertical overhang, above the snow line, out of reach of children, and sufficiently far away from any vents for them not to affect temperature readings. Choose a location protected from direct sunlight. Use caution not to drill screws into any existing electrical wiring or gas lines.

6.Verify operation:

a.Press the WTS button once (Figure 4). The LED should flash five times.

b.Using the AquaSmart’s display, navigate to Screen 1 as shown in Figure 5, in the Navigating the Display Menus Section.

AquaSmart Wireless Termperature Module Manual

5

Page 5
Image 5
Beckett 7600WTM manual Installation, Initial Set-up, How to open WTS, Risk of Fire, Explosion, and Burn Hazard