Beckett 7600WTM manual Operation, AWM Installation, COM Port

Models: 7600WTM

1 12
Download 12 pages 52.54 Kb
Page 4
Image 4
Operation

Operation

The Beckett 7600WTM can help to

 

 

achieve even greater fuel savings over the

The Beckett 7600AWM (AquaSmart

base AquaSmart with the following

advanced features:

 

Wireless Module) dynamically adjusts the

a. Warm Weather Shutdown can be

 

boiler high setpoint using the graph shown

 

in Figure 1 and inputs of the outdoor

enabled to turn the low limit (if used) off

 

temperature and user-configurable

if the outdoor temperature is above

 

setpoints as noted in the figure.

70°F.

The WTM algorithm overrides the

b. The boost function can be adjusted in

 

HeatManagerTM functionality of the base

 

AquaSmart when enabled. If the outdoor

small increments to prevent the reset

 

algorithm from being overridden too

 

sensor battery is depleted or if the sensor

 

quickly, which can benefit systems with

 

stops working for any reason, the AWM will

 

high water mass (such as in-floor

 

revert the AquaSmart back to its

 

radiant heating applications).

 

HeatManagerTM algorithm until the battery

 

 

 

can be replaced.

c. The outdoor reset algorithm begins

In normal operation, the WTS sends the

economizing immediately after a

 

AWM the outdoor temperature every 10 -

Domestic Hot Water (DHW) call for heat,

 

60 minutes. Pressing the WTS button

where the HeatManager takes time to

 

once forces a transmission.

reach full economizing after a DHW call.

 

 

 

Figure 2 - AWM Installation

COM Port

4

Page 4
Image 4
Beckett 7600WTM manual Operation, AWM Installation, COM Port