Figure 2 - Dimensions: Minimum Combustion Chamber and Air Tube Mounting.

* Install burner with 2° pitch as shown.

T

1/4” ± 1/8”

H D *2°

L

E

Firing Rate

Minimum Dimensions

(gph)

 

 

H

L

 

17

10.5”

48.0”

22

11.5”

58.0”

27

12.5”

66.0”

32

12.5”

73.0”

35

13.0”

77.0”

Air Tube Combination Codes

Model

Tube

Dimension

Dimension

Code

Dimension

T

D

E

 

 

 

CF2500A/ CF2500

 

6-3/4”

6-1/2”

CF 66 KP

3-1/4”

KP

10-1/4”

6-1/2”

CF 102 KP

3-1/4”

 

 

13-3/4”

6-1/2”

CF 136 KP

3-1/4”

 

 

 

 

17-3/4”

6-1/2”

CF 176 KP

3-1/4”

 

 

8”

8”

CF 80 KM

4-1/2”

 

 

9-1/4”

8”

CF 92 KM

4-1/2”

CF3500

KM

11-1/2”

8”

CF 114 KM

4-1/2”

 

15”

8”

CF 150 KM

4-1/2”

 

 

 

 

19”

8”

CF 190 KM

4-1/2”

 

 

11-1/2”

9-15/16”

CF 114 KR

5-1/8”

 

KR

14”

9-15/16”

CF 140 KR

5-1/8”

 

 

19”

9-15/16”

CF 190 KR

5-1/8”

 

 

 

 

 

 

Verify Air Tube

The information in this section may be disregarded if the air tube is supplied by the appliance manufacturer.

The following tube arrangements are available –

CF2500 - Tube KP -17.0.0 to 19.9 GPH

CF2500A - Tube KP -17.0 to 25.0 GPH

CF3500A - Tube KM -17.0 to 35.0 GPH or Tube KR -17.0 to 35.0 GPH

Maximum firing capacity depends on the firebox pressure. Use Table 2 to verify the correct air tube type for the firing rate required. (Tube KR [CF3500A] is an optional air tube combination for maximum capacity rate. It requires a larger I.D. flange Number 51631.)

See Figure 2 to verify the correct air tube length and air tube combination code.

Figure 3a - Firebox Pressure: CF2500A with no Reserve Air

U.S. GPH

25

 

 

 

 

 

24

 

 

 

 

 

Rate

 

 

 

 

 

 

 

 

KP

 

 

Firing

 

 

 

 

 

23

 

 

 

 

 

Maximum

22

0.2

0.4

0.6

0.8

1.0

 

0.0

 

 

Firebox Pressure in Inches Water Column (W.C.)

 

Figure 3b - Firebox Pressure: CF3500 with no Reserve Air

U.S. GPH

35

 

 

 

 

 

30

 

 

 

 

 

Firing Rate

 

 

KR

 

 

25

 

 

KM

 

 

Maximum

20

0.2

0.4

0.6

0.8

1.0

 

0.0

 

 

Firebox Pressure in Inches Water Column (W.C.)

 

6

Page 6
Image 6
Beckett CF2500 manual Verify Air Tube, Air Tube Combination Codes