Trouble Shooting Guide
| Problem | Cause | Check | |
| Barbecue will not light | Ignition system not working | Check that there is a visible flame coming from the pilot | |
| ||||
|
|
| ignition tube. | |
|
|
| Check that the pilot ignition tube is not blocked by spider webs | |
|
|
| or insect nests. | |
|
| Turning on gas control too quickly | Allow 5 seconds for gas to flow through burner before ignition | |
|
| No gas flow | Check that valve on gas cylinder is turned on. | |
|
| |||
|
|
| Check that burner ports are free of obstructions | |
|
|
| Check that all gas injectors are clean and free of obstructions | |
|
| Burners not assembled correctly | Check that burners are correctly positioned in the barbecue | |
|
|
| frame. | |
|
| Burner ports or throat blocked | Check that the burner ports are not blocked by spider webs or | |
|
| |||
|
|
| insect nests. Clean out as required | |
| Barbecue lights but goes out | Fuel supply turned off | Turn on gas valve at cylinder (LPG/Propane) or shutoff valve | |
| ||||
| soon after starting |
| on gas line (NG) | |
|
| Gas cylinder low or empty | Refill cylinder with gas (LPG/Propane) | |
|
| |||
|
| Kink in gas hose | Check that the gas line is not kinked or twisted | |
|
| |||
|
| Wind or breeze affecting operation | Ensure that the appliance is located out of the way of wind | |
|
| |||
| Burners will not cross light |
| Check that cross light channel is in place | |
|
| |||
| from one to the other |
| Check that burner ports are free of obstructions. | |
|
|
| ||
| Low flame level or low heat |
| Check you are running on correct gas (NG or LPG/Propane) | |
|
| |||
| output |
| Check gas injector size is correct | |
|
|
| ||
| Stainless steel discolours | Overheating appliance | Do not exceed maximum operating temperatures. | |
| ||||
|
|
|
|
|
Technical Specifications
| Gas | Injector size | Input/burner |
| Gas Pressure | |||
| LPG/Propane | 1.27 mm | 19 MJ/hr |
| 2.75 kPa / 11” WC | |||
| Natural Gas | 2.1 mm | 19 MJ/hr |
| 1 kPa / 4”WC | |||
|
|
|
| 1808/1964 |
| 585 |
| |
|
|
|
| 856/1013 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
165.50 | X | Gas |
|
connection
87 point
1226
920
1212/1372 | 503 |
18