Trouble Shooting Guide

 

ProblemCauseCheck

 

Barbecue will not light

Ignition system not working

Check that there is a visible flame coming from the pilot

 

 

 

 

ignition tube.

 

 

 

Check that the pilot ignition tube is not blocked by spider webs

 

 

 

or insect nests.

 

 

Turning on gas control too quickly

Allow 5 seconds for gas to flow through burner before ignition

 

 

No gas flow

Check that valve on gas cylinder is turned on.

 

 

 

 

 

Check that burner ports are free of obstructions

 

 

 

Check that all gas injectors are clean and free of obstructions

 

 

Burners not assembled correctly

Check that burners are correctly positioned in the barbecue

 

 

 

frame.

 

 

Burner ports or throat blocked

Check that the burner ports are not blocked by spider webs or

 

 

 

 

 

insect nests. Clean out as required

 

Barbecue lights but goes out

Fuel supply turned off

Turn on gas valve at cylinder (LPG/Propane) or shutoff valve

 

 

soon after starting

 

on gas line (NG)

 

 

Gas cylinder low or empty

Refill cylinder with gas (LPG/Propane)

 

 

 

 

Kink in gas hose

Check that the gas line is not kinked or twisted

 

 

 

 

Wind or breeze affecting operation

Ensure that the appliance is located out of the way of wind

 

 

 

Burners will not cross light

 

Check that cross light channel is in place

 

 

 

from one to the other

 

Check that burner ports are free of obstructions.

 

 

 

 

Low flame level or low heat

 

Check you are running on correct gas (NG or LPG/Propane)

 

 

 

output

 

Check gas injector size is correct

 

 

 

 

Stainless steel discolours

Overheating appliance

Do not exceed maximum operating temperatures.

 

 

 

 

 

 

Technical Specifications

 

GasInjector sizeInput/burner

 

Gas Pressure

 

LPG/Propane

1.27 mm

19 MJ/hr

 

2.75 kPa / 11” WC

 

Natural Gas

2.1 mm

19 MJ/hr

 

1 kPa / 4”WC

 

 

 

 

1808/1964

 

585

 

 

 

 

 

856/1013

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

165.50

X

Gas

 

connection

87 point

1226

920

1212/1372

503

18