Beko BK 6300 Step four connect indoor and outdoor pipes, 6WHS¿YHFRQQHFWRXWGRRUHOHFWULFZLUH

Models: BK 5200 BK 6300

1 36
Download 36 pages 45.98 Kb
Page 29
Image 29
Step four: connect indoor and outdoor pipes

Installation of outdoor unit

Step four: connect indoor and outdoor pipes

1.Remove the screw on the right han- dle of outdoor unit and then remove the handle.

screw

handle

2.Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.

 

liquid pipe

liquid

gas pipe

valve

 

 

gas valve

3.Pretightening the union nut with hand.

pipe joint

union nut

4.Tighten the union nut with torque wrench by referring to the sheet below.

Hex nut diameter

Tightening torque

 

(N.m)

ĭ

15~20

ĭ

30~40

ĭ

40~55

ĭ

60~65

ĭ

70~75

6WHS¿YHFRQQHFWRXWGRRUHOHFWULFZLUH

1.Remove the wire clip; connect the power connection wire and signal control wire (only for Heat pump type) to the wiring terminal according to the color; fix them with screws.

1824K Heat pump type:

N(1) 2 3 L N

yellow- green

blue black brown

brown yellow- (black) blue green

L N

Indoor unit connection POWER

26

Page 29
Image 29
Beko BK 6300 Step four connect indoor and outdoor pipes, 6WHS¿YHFRQQHFWRXWGRRUHOHFWULFZLUH, pipe joint union nut