Installation of outdoor unit

2.Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).

Note:

Ɣ$IWHUWLJKWHQWKHVFUHZSXOOWKHSRZHUFRUGVOLJKWO\WRFKHFNLILWLV¿UP Ɣ1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQWKHGLVWDQFH

Step six: neaten the pipes

1.The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.

2.If the outdoor unit is higher than the wall

KROH\RXPXVWVHWD8VKDSHGFXUYHLQWKH

pipe before pipe goes into the room, in order to prevent rain from getting into the room.

wall

U-shaped curve

drain hose

Note:

Ɣ7KHWKURXJKZDOKHLJKWRIGUDLQKRVH

VKRXOGQ WEHKLJKHUWKDQWKHRXWOHW

pipe hole of indoor unit.

the drain hose can't raise

upwards.

Ɣ7KHZDWHURXWOHWFDQ WEHSODFHG in water in order to drain smoothly.

The water outlet can't be placed in water

Ɣ6ODQWWKHGUDLQKRVHVOLJKWO\GRZ

QZDUGV7KHGUDLQKRVHFDQ WEH

FXUYHGUDLVHGDQGÀXFWXDQWHWF

The drain hose can't be fluctuant

The drain hose

 

can't be fluctuant

The water

 

 

outlet can't be

 

fluctuant