Installation of outdoor unit

6WHSRQH¿[WKHVXSSRUWRIRXWGRRUXQLW

(select it according to the actual installation situation)

1.Select installation location according to the house structure.

2.Fix the support of outdoor unit on the selected location with expansion screws.

Note:

Ɣ7DNHVXI¿FLHQWSURWHFWLYHPHDVXUHVZKHQ installing the outdoor unit.

ƔMake sure the support can withstand at least four times of the unit weight.

Ɣ7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVW

FPDERYHWKHÀRRULQRUGHUWRLQVWDOOGUDLQ

joint.

Ɣ)RUWKHXQLWZLWKFRROLQJFDSDFLW\RI:

~5000W, 6 expansion screws are needed; for the unit with cooling capacity of 6000W

~8000W, 8 expansion screws are needed;

for the unit with cooling capacity of 10000W at least 3cm above the floor ~16000W, 10 expansion screws are needed.

Step two: install drain joint (Only for cooling and heating unit)

1.Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.

2.Connect the drain hose into the drain vent.

drain vent chassis

6WHSWKUHH¿[RXWGRRUXQLW

1.Place the outdoor unit on the support.

2.Fix the foot holes of outdoor unit with bolts.

foot holes

foot holes

Drain hose

outdoor drain joint

25

Page 28
Image 28