Pipe expanding method

Note:

Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:

$&XWWKHSLSH Ɣ&RQ¿UPWKHSLSHOHQJWKDFFRUGLQJWR

the distance of indoor unit and outdoor unit.

Ɣ&XWWKHUHTXLUHGSLSHZLWKSLSHFXWWHU

pipe

pipe cutter

leaning uneven burr

B:Remove the burrs

Ɣ5HPRYHWKHEXUUVZLWKVKDSHUDQG prevent the burrs from getting into the pipe.

pipe

shaper

downwards

C:Put on suitable insulating pipe

D:Put on the union nut

Ɣ5HPRYHWKHXQLRQQXWRQWKHLQGRRU connection pipe and outdoor valve; install the union nut on the pipe.

union pipe

pipe

E:Expand the port

Ɣ([SDQGWKHSRUWZLWKH[SDQGHU

hard mold expander

pipe

Note:

Ɣ$LVGLIIHUHQWDFFRUGLQJWRWKH diameter, please refer to the sheet below:

Outer diameter

$ PP

 

 

(mm)

Max

Min

ĭ 

1.3

0.7

ĭ 

1.6

1.0

ĭ 

1.8

1.0

ĭ 

2.4

2.2

 

 

 

F:Inspection

Ɣ&KHFNWKHTXDOLW\RIH[SDQGLQJSRUW

If there is any blemish, expand the port again according to the steps above.

smooth surface

improper expanding

leaning damaged crack uneven

surface thickness

the length is equal

32

Page 35
Image 35
Beko BK 6300, BK 5200 user manual Pipe expanding method, SdqgWkhSruwZlwkHsdqghu, &KhfnWkhTxdolw\RiHsdqglqjSruw