Beko BK 6300, BK 5200 user manual Rq¿JxudwlrqRiFrqqhfwlrqSlsh

Models: BK 5200 BK 6300

1 36
Download 36 pages 45.98 Kb
Page 33
Image 33
&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH

&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH

1.Standard length of connection pipe

ƔPPP

2.Min. length of connection pipe is 3m.

3.Max. length of connection pipe and max. high difference.

Cooling

Max length

Max height

of connec-

capacity

tion pipe

difference

 

 

 

 

 

5000Btu/h

15

5

(1465W)

 

 

7000Btu/h

15

5

(2051W)

 

 

9000Btu/h

15

5

(2637W)

 

 

12000Btu/h

20

10

(3516W)

 

 

18000Btu/h

25

10

(5274W)

 

 

 

 

 

Cooling

Max length

Max height

of connec-

capacity

tion pipe

difference

 

 

24000Btu/h

25

10

(7032W)

 

 

28000Btu/h

30

10

(8204W)

 

 

36000Btu/h

30

20

(10548W)

 

 

42000Btu/h

30

20

(12306W)

 

 

48000Btu/h

30

20

(14064W)

 

 

4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe

Ɣ$IWHUWKHOHQJWKRIFRQQHFWLRQSLSHLVSURORQJHGIRUPDWWKHEDVLVRI standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.

Ɣ7KHFDOFXODWLRQPHWKRGRIDGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW RQWKHEDVLV

of liquid pipe):

$GGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW SURORQJHGOHQJWKRIOLTXLGSLSHî additional refrigerant charging amount per meter

Ɣ:KHQWKHOHQJWKRIFRQQHFWLRQSLSHLVDERYHPDGGUHIULJHUDQWDFFRUGLQJWR

the prolonged length of liquid pipe. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.

30

Page 33
Image 33
Beko BK 6300, BK 5200 user manual Rq¿JxudwlrqRiFrqqhfwlrqSlsh