&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH

1.Standard length of connection pipe

ƔPPP

2.Min. length of connection pipe is 3m.

3.Max. length of connection pipe and max. high difference.

Cooling

Max length

Max height

of connec-

capacity

tion pipe

difference

 

 

 

 

 

5000Btu/h

15

5

(1465W)

 

 

7000Btu/h

15

5

(2051W)

 

 

9000Btu/h

15

5

(2637W)

 

 

12000Btu/h

20

10

(3516W)

 

 

18000Btu/h

25

10

(5274W)

 

 

 

 

 

Cooling

Max length

Max height

of connec-

capacity

tion pipe

difference

 

 

24000Btu/h

25

10

(7032W)

 

 

28000Btu/h

30

10

(8204W)

 

 

36000Btu/h

30

20

(10548W)

 

 

42000Btu/h

30

20

(12306W)

 

 

48000Btu/h

30

20

(14064W)

 

 

4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe

Ɣ$IWHUWKHOHQJWKRIFRQQHFWLRQSLSHLVSURORQJHGIRUPDWWKHEDVLVRI standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.

Ɣ7KHFDOFXODWLRQPHWKRGRIDGGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW RQWKHEDVLV

of liquid pipe):

$GGLWLRQDOUHIULJHUDQWFKDUJLQJDPRXQW SURORQJHGOHQJWKRIOLTXLGSLSHî additional refrigerant charging amount per meter

Ɣ:KHQWKHOHQJWKRIFRQQHFWLRQSLSHLVDERYHPDGGUHIULJHUDQWDFFRUGLQJWR

the prolonged length of liquid pipe. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.