27 GB
Programme Table
Programme number | 1 | 2 | 3 Reference** | 4 | 5 | 6 | 7 | 8 | |
|
|
|
|
|
|
|
|
| |
Programme name | Rapid | Eco | Quick & Clean | Intensive | Hygiene | WASH@ONCE | Auto Sensing | ||
|
|
|
|
|
|
|
|
| |
Cleaning temperature | - | 35 °C | 50 °C | 60 °C | 70 °C | 70 °C | 70 °C | ||
|
|
|
|
|
|
|
|
| |
| Lightly soiled dishes, | Most economic | Lightly soiled dishes, | Heavily soiled dishes | With extra rinse cycle | The best programme | Automatically senses | ||
| and loosen residue | 30 minute | programme for | A class cleaning in | requiring | recommended for | for the mixed nature | water dirtiness | |
| - awaiting full | programme | normally soiled | 58 minutes | Hot | toddler | of the daily load and | level and washes | |
| load - then select a |
| dishes |
|
| dishes and bottles. | plastic items. | until dishes are | |
Degree of soiling | Programme |
|
|
|
|
|
| completely cleaned | |
|
|
|
|
|
|
|
|
| |
| - | Few | Medium | Medium | High | High | High | Medium to high | |
|
|
|
|
|
|
|
|
| |
Detergents | - | A | A+B | A+B | A+B | A+B | A+B | A | |
A=25 cm³/15 cm³ B=5 cm³ | |||||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
| Wash | Wash | The programme | ||||||
| ▼ | ▼ | ▼ | ▼ | ▼ | ▼ | ▼ | sequence is adjusted | |
| End | Cold rinse | Wash | Cold rinse | Wash | Wash | Wash | to the amount of | |
|
| ▼ | ▼ | ▼ | ▼ | ▼ | ▼ | soiling | |
|
| Hot Rinse | Cold rinse | Hot Rinse | Cold rinse | Cold rinse | Cold rinse |
| |
|
| ▼ | ▼ | ▼ | ▼ | ▼ | ▼ |
| |
Programme sequence |
| End | Hot Rinse | Dry | Hot Rinse | Rinse | Rinse |
| |
(without options) |
|
| ▼ | ▼ | ▼ | ▼ | ▼ |
| |
|
|
| Dry | End | Dry | Hot Rinse | Hot Rinse |
| |
|
|
| ▼ |
| ▼ | ▼ | ▼ |
| |
|
|
| End |
| End | Dry | Dry |
| |
|
|
|
|
|
| ▼ | ▼ |
| |
|
|
|
|
|
| End | End |
| |
|
|
|
|
|
|
|
|
| |
Duration (min) | 15 | 30 | 167 | 58 | 143 | 124 | 177 | ||
|
|
|
|
|
|
|
|
| |
Water (I) | 4 | 10,4 | 6 | 10,2 | 16,2 | 17,8 | 18,6 | ||
|
|
|
|
|
|
|
|
| |
Energy (kWh) | - | 0,8 | 1,03 | 1,32 | 1,26 | 1,97 | 1,36 | ||
|
|
|
|
|
|
|
|
|
The consumption values shown in the table were determined under standard conditions. Differences may therefore occur under practical conditions.
*The consumption figures and duration of the programmes marked with
**Reference programme for testing institutes
The tests in accordance with EN 50242 must be carried out with a full water softener salt dispenser and a full rinse aid reservoir, and using the test programme.