Operating Instructions
Air Circulation Mode
Circulates the room air without cooling or heating.
1Press the Start/Stop button. the unit will respond with a beep.
Open the door on the remote control. Press the Air Circulation button. Close the door on the
2remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.
ENGLISH
CHAOS Air | Fan speed is on low. Fan speed is on medium. Fan speed is on high. |
NOTICE
o CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.
Forced Operation
Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation,
Power button
Open the front panel upward
| Cooling Model |
| Heat pump Model |
|
|
| Room Temp. ≥ 24°C | 21°C ″ Room Temp. < 24°C | Room Temp. < 21°C |
Operating mode | Cooling | Cooling | Healthy Dehumidification | Heating |
Indoor FAN Speed | High | High | High | High |
Setting Temperature | 22°C | 22°C | 23°C | 24°C |
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about 3 seconds.
If you want to stop the operation,
For this operation L0 appears on the display. (Plasma model only)
Auto restart(Optional)
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Additionally, in order to cancel auto restart operation press power button let it be pressed for about
6 seconds. To operate auto restart operation again, press power button for about 6 seconds as well.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly.
High
Speed
Owner’s Manual 19