Belkin DLA-HD2KE, DLA-HD2KU service manual DC adjustment, „Measurement

Models: DLA-HD2KU DLA-HD2KE

1 34
Download 34 pages 48.91 Kb
Page 22
Image 22

4.4.2 DC adjustment

Instruments

PSA Software for HD2K

REPLACING COMPONENTS

 

Excel file for GAMMA adjustment

z DD SUB1.2 PWB ASS'Y

 

Color-meter (CL-200)

z OPTICAL BLOCK

 

 

 

Test point

 

 

 

 

 

Adjustment menu

< DDIC > < Gamma >

 

 

 

 

Preparation

Running the unit enough before adjustment.

 

 

 

 

„PREPARATION

(1)Connect the PC and Projector, PC and CL200 with RS-232C cables and then turn the Projector ON.

(2)Boot the SPA software.

(3)Click [Connect] on the Menu Bar and select [Auto Connect] in the pull-down menu. Refer to Fig.1.

Set these parameters to ON

Fig.1

Fig.2

(4)When the connection is completed, press the [DDIC] button. The [DDIC Control] screen will appear.

(5)Press the [Receive All] button at the top right of the screen.

(6)Press the [R] button at the top left of the screen. Of the buttons located at the furthest right of the screen, set [GINDAT], [SUPDA][DCSDAT] and [RVSDAT] to ON, and the rest to [OFF].

Refer to Fig.2

(7)Click [DisConnect] in the PSA menu to disconnect the connection.

(8)Put the CL200 at 40cm away from the projector lens surface (Screen center) and turn the CL200 to ON.

„MEASUREMENT

(9)Open the Gamma adjustment file and click [CONNECT] in the [DC] sheet.

(10)Click [MEASURE] when [OK] is shown. Refer to Fig.3.

(10)Click here

(9)Click here

Confirm [OK]

Fig.3

(11)When the measurement is completed, click [CONNECT] in step 10) to disconnect the system. Boot the PSA software to connect the PC and the Projector.

(12)On completion of the measurement, enter the values in red in the [D43], [T43] and [AJ43] cells to [DC_R], [DC_G] and [DC_B], respectively.

(13)Click [DisConnect] in the PSA screen to disconnect the system. The Gamma adjustment is to be performed next.

1-22 (No.PA019)