SECTION 5

TROUBLESHOOTING

5.1PROTECTIVE SENSOR AND PROTECTIVE SWITCH

In event of abnormal operation due to circuit or component failure, setting error or other reason, in order to prevent serious damage to the set and preserve the integrity of peripheral equipment, sensors and switches are provided for protective functions. Cooling is conducted at the same time a corresponding LED flashes (about 90 seconds). The LED indication with respect to the protective func- tion is described below.

5.1.1 Protective sensor

Type

Monitor objective

Location

Operating point

Function

 

 

 

 

 

Thermal sensor

Lamp unit

Optical block (Lamp section)

140°C

AC line (one side) open

(Thermostat)

 

 

 

 

 

 

 

 

 

Thermal sensor (IC)

Set interior

MAIN PWB ASS'Y IC728

70°C

Power off by main CPU (emergency mode)

 

(Lamp area)

 

 

 

 

 

 

 

 

Thermal sensor (IC)

Set exterior

MAIN PWB ASS'Y IC727

62°C

Power off by main CPU (emergency mode)

 

(Filter area)

 

 

 

Motor operation

Cooling fan

Cooling fan interior

Fan stop

Power off by main CPU (emergency mode)

detection circuit

 

 

 

 

 

 

 

 

 

5.1.2 Protective switch

Type

Monitor objective

Location

Operating point

Function

 

 

 

 

 

Interlock switch

Lamp cover

Optical block (Lamp section)

Switch open

Control by CPU

 

 

 

 

 

5.2LED (INDICATOR) WARNING INDICATIONS

5.2.1 Led indication contents

If an abnormality occurs during operation (projection), the content of the problem can be determined from flashing LED indicators. When an LED indicates, operation (projection) automatically stops and the cool-down mode (about 90 seconds) is entered (except for No.1, No.3, No.4, No.5 and No.6), then the stand-by mode.

No.

 

Flashing LED

 

Flash time

Warning cause (projector mode)

 

 

 

 

 

 

 

 

LAMP

TEMP

STAND BY

OPERATE

 

 

 

 

 

 

 

 

 

1

z

 

z

 

0.5sec.

Lamp not lighted cannot project

 

 

 

 

 

 

 

2

z

 

 

z

0.5sec.

Lamp extinguishes during projection Lamp use time ex-

 

 

ceeds 2010 hours

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

0.5sec.

Lamp terminal not contact

 

 

 

 

 

 

 

4

z

z

 

 

0.5sec.

Sub CPU circuit error

 

 

 

 

 

 

 

5

z

z

 

 

0.25sec.

Device drive circuit error

 

 

 

 

 

 

 

6

 

 

0.5sec.

Video process circuit (decoder) error

 

 

 

 

 

 

 

7

 

 

0.25sec.

Video system error after data initializing

 

 

 

 

 

 

 

8

 

z

 

 

0.5sec.

Set interior abnormally hot

 

 

 

 

 

 

 

9

 

z

z

 

0.5sec.

Air intake temperature too high (exterior temperature

 

 

abnormal)

 

 

 

 

 

 

 

 

 

 

 

 

 

10

z

z

z

z

0.5sec.

Set internal cooling fan stopped (fan locked)

 

 

 

 

 

 

 

11

z

 

 

 

0.5sec.

Lamp use time exceeds 2000 hours

 

 

 

 

 

 

 

z : Flashing together

: Flashing alternately

 

 

 

(No.PA019)1-31