8. Fine-tune the LF equalization to remove ‘black video smearing’ - black smears to the
right of large objects such as window title bars (see Figure 11).
LF Equalization Commands Key Sequence
Increase LF Equalization (Coarse)
Decrease LF Equalization (Coarse)
<L> + <Up Arrow>
<L> + <Down Arrow>
Increase LF Equalization (Fine)
Decrease LF Equalization (Fine)
<L> + <Right Arrow>
<L> + <Left Arrow>
9. Fine-tune the HF equalization to sharpen the video image. Increase HF Equalization
until a white edge to the right of small characters just starts to appear (see Figure 11).
HF Equalization Commands Key Sequence
Increase HF Equalization (Coarse)
Decrease HF Equalization (Coarse)
<H> + <Up Arrow>
<H> + <Down Arrow>
Increase HF Equalization (Fine)
Decrease HF Equalization (Fine)
<H> + <Right Arrow>
<H> + <Left Arrow>
10. If you are using one or more flat panel monitors in the Remote consoles, carry out auto-
adjustment again.
11. Save the settings by pressing the <Es c> key. Alternatively, to discard any changes and
revert to the settings stored in the EEPROM, press <Left Control> + <Esc>. The
Remote unit automatically exits Command Mode after 30 sec of inactivity and saves all
settings, including any changes.