Broadcast Alarm Status

Optional Module Broadcast Packet Rate Threshold: The number of broadcast packets received on a given optional module per second. The range is 0 to 14,880 packets per second.

Port Broadcast Packet Rate Threshold: The number of broadcast packets received on a given port per second. The range is 0 to 14,880 packets per second.

Broadcast Alarm Action: Once a broadcast storm is detected on a given port, the Alarm Detection Status will be set to Detected, and the proper action shall be performed based on the value specified by its Broadcast Alarm Action.

Partition: The port will be disabled. Once a port is partitioned due to broadcast storm, the Broadcast Storm protection function will continue to monitor the port based on the following rule:

a)The port is disabled for 15 seconds, enabled again for 5 seconds.

b)If the storm exists for 2 minutes, the port is disabled and not monitored.

NOTE: It is up to the user to enable the port once the source of the broadcast storm has been handled.

Send Trap and Partition: The port will be disabled and a trap will be sent.

Send Trap: A trap is sent.

No Action: No action will be taken.

Broadcast Alarm Status

Enable: Enable the broadcast monitoring and protection function on this segment

Disable: Disable the broadcast monitoring and protection function on this segment

Invalid: Purge the broadcast monitoring and protection setting for this segment