Black Box LH8124A, LH8112A-S manual 52 10/100 Managed Hub, Unit Configuration

Models: LH8112A LH8112A-S LH8124A

1 132
Download 132 pages 41.46 Kb
Page 52
Image 52
Unit Configuration

4.Press <Next> to scroll through each configuration item.

5.Press <Enter> to apply the currently displayed configuration to the port.

The applied configuration is indicated by an asterisk sign displayed before the name of the configuration in the Message Zone as shown below, otherwise, the asterisk sign does not appear.

K % 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 G-A

80

G-B

40

G-C

20

G-D

10

5

ID

3

Master

1

WWW

 

SNMP

 

O-O-B

Current Port Configuration (single port)

The table lists typical default settings and the possible optional settings for a port. An “*” appears before each current setting. To change a setting, press and hold down Enter until an “*” appears before the desired setting, the “*” is removed from the previous setting.

Port Setting

Default

Optional Settings

 

 

*AUTO-NEGO

10BASE-T/100BASE-X

 

 

*ENABLE

Disable

 

 

Unit Configuration

You can configure the hub using the Unit Configuration Menu. For security reasons you are prompted for the password when the device is locked. Without the password users cannot enter the Unit Configuration menu in order to change any unit configurations. When the device is unlocked, no password verification is required to change the unit configu- rations. The password entry is described in “Set Password.”

52 10/100 Managed Hub

Page 52
Image 52
Black Box LH8124A, LH8112A-S manual 52 10/100 Managed Hub, Unit Configuration