Stop Bits: 1 stop bit

Out-of-Band Operation Mode

Baud Rate: The baud rate can be configured as one from 2400bps, 4800bps, 9600bps, 19200bps. The default is 9600.

Character Size: 8 bits character size

Parity: No parity.

Stop Bits: 1 stop bit

Select <Save> to retain the new configuration. The new configuration takes effect if Out-of-Band management is enabled.

When SLIP is enabled, the EIA 232 port can be used for SLIP only. The EIA 232 port cannot be used to gain access to a management session via VT100 terminal emulation. If the SLIP connection is malfunctioning, you can disable SLIP by rebooting and pressing <Enter> when the Abort message appears. The message will appear for only 10 seconds. OOB also appears on the lower right side of the Mini Console. You can also establish a Telenet session and modify the serial port configuration.

Master Hub Configuration & Console Management 73